Blank pieces of pipe fittings and welded assemblies at ST CKBA 016-2005. Quenching in water with 1090-1110 °C (exposure 6 h) + Triple speed aging: Aging at 990-1010 °C (exposure 2 hours), cooled with furnace + Aging at 890-910 °C (aging for 1 h), cooling with the furnace + Aging at 790-810 °C (exposure 2 hours), air cooling + Ageing at 730-770 °C (20 h exposure), air cooling |
≤55 |
≥441 |
≥833 |
≥18 |
≥18 |
≥588 |
207-241 |
Rod. Annealing in air from 1100 °C (maintained for 5 h) + step-Aging: 1000 °C (exposure 2 hours), cooled with the furnace to 900 °C, exposure for 1 h, cooling with the furnace to 800 °C, exposure 2 h, air cooling + Ageing at 750 °C (20 h exposure), air cooling + Ageing at 650 °C (extract 48 h), cooling air (indicated by temperature and duration of heat exposure) |
- |
≥770 |
≥1180 |
≥22 |
≥29 |
- |
- |
- |
≥690 |
≥1050 |
≥21 |
≥31 |
- |
- |
A sample with a diameter of 6 mm, length 30 mm, extruded tempered and aged. The rate of deformation of 16 mm/min strain Rate of 0.009 1/s |
- |
- |
≥570 |
- |
≥97 |
- |
- |
Rod. Annealing in air from 1100 °C (for longitudinal samples) |
≤30 |
≥650 |
≥950 |
≥18 |
≥22 |
≥687 |
- |
Rod. Annealing in air from 1100 °C (maintained for 5 h) + step-Aging: 1000 °C (exposure 2 hours), cooled with the furnace to 900 °C, exposure for 1 h, cooling with the furnace to 800 °C, exposure 2 h, air cooling + Ageing at 750 °C (20 h exposure), air cooling + Ageing at 650 °C (extract 48 h), cooling air (indicated by temperature and duration of heat exposure) |
- |
≥800 |
≥1200 |
≥19 |
≥23 |
- |
- |
- |
≥560 |
≥850 |
≥5 |
≥13 |
- |
- |
A sample with a diameter of 6 mm, length 30 mm, extruded tempered and aged. The rate of deformation of 16 mm/min strain Rate of 0.009 1/s |
- |
- |
≥410 |
≥77 |
≥96 |
- |
- |
Rod. Annealing in air from 1100 °C (maintained for 5 h) + step-Aging: 1000 °C (exposure 2 hours), cooled with the furnace to 900 °C, exposure for 1 h, cooling with the furnace to 800 °C, exposure 2 h, air cooling + Ageing at 750 °C (20 h exposure), air cooling + Ageing at 650 °C (extract 48 h), cooling air (indicated by temperature and duration of heat exposure) |
- |
≥440 |
≥920 |
≥33 |
≥42 |
- |
- |
- |
≥360 |
≥590 |
≥16 |
≥18 |
- |
- |
A sample with a diameter of 6 mm, length 30 mm, extruded tempered and aged. The rate of deformation of 16 mm/min strain Rate of 0.009 1/s |
- |
- |
≥295 |
≥78 |
≥96 |
- |
- |
Rod. Annealing in air from 1100 °C (maintained for 5 h) + step-Aging: 1000 °C (exposure 2 hours), cooled with the furnace to 900 °C, exposure for 1 h, cooling with the furnace to 800 °C, exposure 2 h, air cooling + Ageing at 750 °C (20 h exposure), air cooling + Ageing at 650 °C (extract 48 h), cooling air (indicated by temperature and duration of heat exposure) |
- |
≥440 |
≥920 |
≥24 |
≥32 |
- |
- |
- |
≥320 |
≥570 |
≥16 |
≥20 |
- |
- |
A sample with a diameter of 6 mm, length 30 mm, extruded tempered and aged. The rate of deformation of 16 mm/min strain Rate of 0.009 1/s |
- |
- |
≥165 |
≥84 |
≥98 |
- |
- |
Rod. Annealing in air from 1100 °C (maintained for 5 h) + step-Aging: 1000 °C (exposure 2 hours), cooled with the furnace to 900 °C, exposure for 1 h, cooling with the furnace to 800 °C, exposure 2 h, air cooling + Ageing at 750 °C (20 h exposure), air cooling + Ageing at 650 °C (extract 48 h), cooling air (indicated by temperature and duration of heat exposure) |
- |
≥640 |
≥930 |
≥18 |
≥22 |
- |
217-255 |
A sample with a diameter of 6 mm, length 30 mm, extruded tempered and aged. The rate of deformation of 16 mm/min strain Rate of 0.009 1/s |
- |
- |
≥120 |
≥100 |
≥100 |
- |
- |
Rod. Annealing in air from 1100 °C (maintained for 5 h) + step-Aging: 1000 °C (exposure 2 hours), cooled with the furnace to 900 °C, exposure for 1 h, cooling with the furnace to 800 °C, exposure 2 h, air cooling |
- |
≥640 |
≥1030 |
24-30 |
28-35 |
≥961 |
- |
- |
≥600 |
≥980 |
≥26 |
≥26 |
- |
- |
- |
≥590 |
≥810 |
≥11 |
≥14 |
- |
- |
- |
≥540 |
690-730 |
7-12 |
10-15 |
- |
- |
- |
≥490 |
≥670 |
≥7 |
≥6 |
- |
- |